Circuit board 2. Suppressor 3. Main switch on programme selector 4. Door safety interlock 5. Anti-boiling pressure switch 7. Anti-overflow pressure switch certain models only 8.
Heating element 9. Stator motor Overload circuit-breaker motor Tachymetric generator motor Rotor motor Drain pump Pre-wash solenoid valve Washing solenoid valve In case of burning on the main circuit board, check that the problem is not caused by another electrical component short-circuits, poor insulation, water leakage. Refer to the figures below in order to identify the component that might have caused the burning according to the position of the burned area.
The circuit board shown below is the version with the greatest number of components: other boards may not feature all these components relay K4 and buzzer. Free Download. Circuit Diagram. Car Stereo Wiring.
Car Manuals. Service Manual. Zanussi washing machine wiring diagram service manual error code circuit schematic schema repair instruction guide user manual free p df download. Circuit board. Main switch on programme selector. Door safety interlock. Anti-boiling pressure switch. Anti-overflow pressure switch certain models only. Heating element. Stator motor.
Overload circuit-breaker motor. Tachymetric generator motor. Rotor motor. Drain pump. North London Appliances Repair forums. Ask a Question Discussions. Comments 0. Rated 0 out of 5 based on 0 voters. There are no comments posted here yet. Leave your comments. Posting comment as a guest. Sign up or login to your account. Name Required. Email Required. Rate this post:.
Reset Rating. Share Your Location. Also subscribe me to this thread. Agree to terms and condition. Interlock power supply triac faulty. Safety drain cycle Cycle blocked. Door interlock sensor faulty. Door interlock sensing circuit triac faulty. Motor power supply triac short-circuited. PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked after 5 attempts. No signal from motor tachometric generator. Motor faulty; wiring faulty; PCB faulty. Motor triac sensing circuit faulty. Motor relay contacts sticking. Motor defective; Wiring defective on inverter for motor, inverter board defective. Motor defective; Wiring defective on inverter for motor, inverter board defective, abnormal motor operation motor overloaded.
No signal from tachometric generator for more than 3 seconds. Motor defective; Wiring defective on inverter for motor; Inverter board defective. Overheating on heat dissipater for inverter. Inverter board defective. Overheating caused by continuous operation or ambient conditions let appliance cool down. Input voltage is lower than V. Wiring defective, Inverter board defective. Input voltage is too high. Inverter board defective, the mains voltage is too high measure the mains voltage.
Data transfer error between inverter and main board. Line interference, Wiring defective, defective main board or inverter board. Communication error between inverter and main board.
Defective wiring between main board and inverter board, Defective inverter board, defective main board. Inverter board fails to start the motor.
Defective inverter board, Defective wiring, defective main board. Insufficient heating during wash cycle. Heating phase is skipped.
Overheating during wash cycle. Safety drain cycle - Cycle stops with door unlocked. Relay supplying power to heating element defective. Main board defective; Electrical current leak from heating element to ground. NTC sensor for wash cycle defective. Heating is skipped. Drying NTC sensor condenser defective; wiring defective; main circuit board defective. Drying NTC sensor duct defective; wiring defective; main circuit board defective. NTC sensor for wash cycle improperly positioned.
Error in selector reset position. PCB faulty Wrong configuration data. Selector, wiring. Error in reading selector. Cycle cancelled. Recirculation pump defective inconsistency between the state of the sensing circuit for the recirculation pump and the state of the triac.
Recirculation pump; Wiring; Main board;. Machine drains and cycle stops with door unlocked. Defective sensing circuit on triac for recirculation pump input voltage on microprocessor remains at 0 or 5 V. Main board. Communication error between main board and display board. Inconsistency in communication between main board and display board versions not compatible.
Configuration error on appliance. Main board defective Improper programming. Configuration error on wash cycle. Inconsistency between list of programmes and configuration of cycle. Communication error between microprocessor and clock.
Display board faulty. The cycle continues. Frequency of power supplied to appliance out of limits. Input voltage too high. Input voltage too low. Inconsistency between safety relay and sensing circuit.